| Models | SDU 5000 |
|---|---|
| INPUT | |
| Dual input | no |
| Rated power | 5000 VA |
| Voltage | 220 / 230 / 240 V |
| Voltage tolerance | 230 V ±20% full load / 230 V +20% -40% half load |
| Frequency | 50 / 60 Hz ±5 |
| Power factor | >0.98 |
| Current distorsion | ≤2% |
| BY PASS | |
| Voltage tolerance | 180 / 264 V (selectable in ECO Mode or SMART ACTIVE Mode) |
| Frequency tolerance | Selected frequency ±5% (selectable by user) |
| OUTPUT and INVERTER OUTPUT | |
| Rated power | 5000 VA |
| Active power | 5000 W |
| Rated voltage | 220 / 230 / 240 V selectable |
| Crest factor (Ipeak/Irms) | 3 : 1 |
| Waveform | Sinusoidal |
| Frequency | 50 / 60 Hz selectable |
| Voltage distortion with non-linear load | <3% |
| Voltage distortion with linear load | <1% |
| BATTERIES | |
| Type | VRLA AGM maintenance-free lead based |
| Typical recharge time | 4-6 h |
| ENVIRONMENTAL | |
| Color | Black RAL 9005 |
| Communication | USB / RS232 / slot for communications interface / REPO + Input contact |
| Accessories provided | USB cable; handles kit |
| Protections | Overcurrent – short circuit – overvoltage – undervoltage – temperature – excessive low battery |
| Noise (at 1 m) | <48 [bBA] (ECO Mode) |
| Operating temperature | 0 °C – +40 °C |
| Relative humidity | 5-95% non-condensing |
| Output sockets | Terminal block + 2 IEC 320 C13 – PDIST / ER: Terminal block + 8 IEC 320 C13 + 2 IEC 320 C19 |
| Standards | European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility — Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant — Classification in accordance with IEC 62040-3 VFI – SS – 111 |
| DATA | |
| Weight | 45 kg |
| Dimensions (h w d) | 448x131x640 Tower – 3Ux19”x640 Rack mm |
| Input phases | 1 |
| Output phases | 1 |
Riello Sentinel Dual Online UPS 5000VA
Sentinel Dual SDU
Installation flexibility and quality power
Sentinel Dual (SDU) is a doubly-versatile UPS providing maximum protection to critical loads in server rooms, electro-medical devices, IT networks and industrial applications. Install as a rackmount UPS or freestanding tower.
High Quality Power
SDU delivers unity power (except 4 kVA version) and 95% operating efficiency in ONLINE double conversion mode. High overload (up to 150%) and short circuit capacity. Designed to deal with non-linear loads with a crest factor up to 3:1.
Fantastic Flexibility
Choice of 5 power ratings plus extended runtime models (6 kVA and 10 kVA models) for longer autonomy. Tower or rackmount installation. Parallel up to 3 UPS together to increase power, redundancy or battery runtime.